ESS Test Chamber


Model

ESS225

ESS408

ESS800

ESS1000

ESS1500

Inner volume (L)

225

408

800

1000

1500

Temperature range

-70°C~180°C(A:5°C/min; B:10°C/min; C:15°C/min; D:20°C/min)

Linear/Nonlinear

Humidity range

20.0%RH~98.0%RH


Surface temperature control of sample and environmental temperature control technology in test area

Meet the stress screening and lead-free process of electronic equipment products、MIL-STD-2164、MIL-344A-4-16、 MIL-2164A-19、NABMAT-9492、GJB-1032-90、GJB/Z34-5.1.6、IPC-9701...and other test requirements.

Different stress can be set to screen the temperature change rate:5℃/min、10℃/min、15℃/min、20℃/min.

Can perform rapid temperature change (stress screening), condensation test, high temperature and high humidity, temperature and humidity cycle, etc.

Meet the stress screening test requirements for electronic equipment products.

Executable equal temperature and average temperature test. Complete real-time test curve analysis shows no time limit

Two-zone/Three thermal Shock Test Chamber


Model

THS50

THS80

THS150

THS200

THS300

Inner volume (L)

50

80

150

200

300

Temperature range

-55°C~+150°C (A: -40°C~+150°C; B: -55°C~+150°C;)

Transfer time

3 seconds

Recovery time

5 — 10 min


Two-zone/Three thermal Shock Test Chamber

The high-precision refrigeration system controls the cooling capacity with high precision and achieves significant energy savings

Safety Standards: Safety of machinery (ISO 12 100,) Low voltages (IEC 60 204,) and EMC (IEC 61 000−6-2 and IEC 61 000−6-4)

Uniform thermal stress performance.

Optimal mechanism and high efficiency refrigeration machinery design.

Mobile APP/ computer remote control.

Cooling mode supports air cooling and water cooling.

UV lamp Weathering Test Chamber


Standards

ASTM D4799, ASTM D6662.J15K 5600-7-8.AATCC TM186,ASTM G154.ASTM D4587.EN 927-6,ISO 11507,ISO 4892-3,SAE J2020


The UV lamp accelerated weathering test chamber uses a fluorescent ultraviolet lamp as a light source, and appropriately controls the temperature and humidity to periodically generate condensation on the sample, thereby comprehensively

obtaining the damage effect of sunlight, moisture and temperature on the polymer material.

External dimension 1360×520×1310mm (WxDxH)

Effective exposure area 5175cm2/828in2

Irradiance setting range 0.3W/m2 ~1.0 W/m2

Light source UV-A(wavelength 340nm)or UV-B(wavelength 313nm); 40W×8pcs ( normal service life: 6000h)

SUN Xenon Lamp Weathering Test Chamber


Model

SXW50

SXW100

SXW600

SXW1000

SXW3600

Inner volume (L)

50

100

600

1000

3600

Testing standards

AATCC TM169、ASTM C1442、ASTM C1501、ASTM D4355、ASTM D6695、ASTM G151、ASTM G155、ISO 105-B06、ISO 105-B10、MIL-STD 810G


Equipped with three different filter systems to obtain spectra of different energy distributions

A. Daylight filter: simulates the spectral distribution of ultraviolet and visible light of solar radiation (equivalent to outdoor direct sunlight), and has the best correlation with most outdoor practical applications. It is used to test outdoor materials, called artificial weather aging test.

B. Window glass filter: simulates the spectral distribution of ultraviolet and visible light of the window glass after passing through 3mm(corresponding to the sunlight transmitted through the window glass). It is used for testing indoor materials, called artificial radiation exposure.

Light source: 1.8KW imported air-cooled xenon lamp or 1.8KW domestic xenon lamp (normal service life is about 1500 hours)

Effective exposure area: 1,000cm2 (9 pieces of 150×70mm samples can be placed at a time)

Irradiance setting range: Chinese Xenon lamp: 30W/m2~100W/m2 (300nm~400nm) or 0.3 W/m2~0.8 W/m2 (@ 340nm) or 0.5 W/m2~1.5 W/m2 (@ 420nm)

*Optional: Ameircan Xenon lamp: 50W/m2~120W/m2 (300nm~400nm) or 0.3 W/m2~1.0 W/m2 (@ 340nm) or 0.5 W/m2~1.8 W/m2 (@ 420nm)

Support lighting function, no spray, no humidity, no temperature function

B-SUN Xenon Lamp

Adjustable Irradiance Range:

0.3~0.75 W/m2 (Single point of control:340nm)

0.5~1.35 W/m2 (Single point of control:420nm)

30 W/m2~90 W/m2 (Full spectrum :from 300~400nm)

Q-SUN Xenon Lamp:

Irradiance setting range

30W/m2~150W/m2 (Full spectrum 300-400nm)or

0.3W/ m2~1.5W/m2 @340nm or 0.5W/ m2~2.7 W/m2@420nm

Rain Test Chamber (IPX-9K)

Water spray angle

0、30、60、90 degree(4 positions)

Water flow

14-16L/min

Testing room dimensions (mm)


1000(W) x 1080(H) x 1050(D)