Model | 10M | 20M | 50M | 100M | 200M | 300M | 600M |
Max testing force(KN) | 10 | 20 | 50 | 100 | 200 | 300 | 600 |
Accuracy Class | Class 0.5 | ||||||
Force Measurement Range | Standard :2%~100%FS; Optional:0.4%~100%FS | ||||||
Accuracy Of Test Force | within ±0.5% | ||||||
Speed Accuracy | within ±0.5% set speed | ||||||
Resolution Of Displacement | 0.001mm | ||||||
Deformation Measurement Range | 2%~100%FS | ||||||
Test Width(mm) | Standard:360mm,400mm,520mm(can be customized) | ||||||
Standards | ASTMA370, ASTME4, ASTME8, ASTME9, ISO6892, ISO7438, ISO7500-1, EN10002-4, GB/T228, GB16491, HGT3844, QB11130, GB13-22, HGT3849, GB6349, GB/T1040.2, ASTM C165, EN826, EN1606, EN1607, EN12430 |
Model | 2000D | 1000D |
Max testing force(KN) | 2000 | 1000 |
Accuracy Class | Class 0.5 | Class 0.5 |
Force Measurement Range | 40-2000kN | 40-1000kN |
Accuracy Of Test Force | ≤ ±1% | ≤ ±1% |
Displacement Accuracy | ≤ ±1% | ≤ ±1% |
Resolution Of Displacement | 0.01mm | 0.01mm |
Max Piston Moving Speed | 50mm/min | 50mm/min |
Clamping Method | Hydraulic clamp | Hydraulic clamp |
Maximum tensile space (mm) | 650 | 650 |
Maximum Compression Test Space(mm) | 600 | 600 |
Piston Stroke(mm) | 250 | 250 |
Model | 2000D | 1000D |
Max testing force(KN) | 2000 | 1000 |
Accuracy Class | Class 0.5 | Class 0.5 |
The maximum distance between the upper and lower pressing plates | 400 mm | |
Accuracy Of Test Force | ≤ ±1% | ≤ ±1% |
Displacement Accuracy | ≤ ±1% | ≤ ±1% |
The maximum selection range of the piston | 100 mm | |
Upper pressure plate specification | 375x400 mm | |
Lower plate specification | 375x400 mm |